Abstract
Pressure drop experiments for a natural refrigerant vaporization of CO 2 were performed in horizontal minichannels. The test section was made of stainless steel tubes with inner diameters of 1.5 mm and 3.0 mm and with lengths of 2000 and 3000 mm. This test section was uniformly heated by applying electric current directly to the tubes. Experiments were performed at inlet saturation temperatures of −10, −5 and 10 °C, mass flux ranges from 200 to 600 kg m −2 s −1 and heat flux ranges from 10 to 30 kW m −2. The current study showed the significant effect of mass flux, tube diameter, and saturation temperature on the pressure drop. The experimental results were compared against 13 existing two-phase pressure drop prediction methods. A new pressure drop prediction method based on the Lockhart–Martinelli method was developed with 9.41% mean deviation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.