Abstract
Recently a great attention has been given to the oscillatory flow modeling in the pulse tube cryocoolers. In this paper multi dimensioning effects of the fluid flow in the pulse tube are investigated. A complete system of governing equations is solved to report the flow field, friction coefficient and Nusselt number in the pulse tube. Harmonic approximation technique is employed to derive an analytical solution. In this respect, mass, momentum and energy balance equations as well as the equation of state for ideal gas are transformed by implementing the harmonic approximation technique. The present model is able to predict the behavior of the two dimensional compressible oscillatory flow in the tube section of the regenerative cryocoolers. Based on the proposed analytical model, friction coefficient and complex Nusselt number is reported.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.