Abstract

One of the most important applications of a reverberation chamber is for radiated power measurement. Two new alternative methods are proposed to measure the radiated power of equipment under test in a reverberation chamber in this paper. Traditionally, as stated in IEC 61000-4-21 standard, this measurement requires two antennas, a signal generator and a spectrum analyzer or receiver. However, it is found that if a signal generator is not available, a vector network analyzer can be used to complete the measurement. Furthermore, if only one antenna is available, by taking advantage of the enhanced backscattering effect, the measurement can still be completed. By incorporating the one- and/or two-antenna methods, the radiation efficiency of antennas is also considered. Measurements have been conducted to verify the proposed methods, the results from these three methods are compared, and a very good agreement is obtained. It is found that the two proposed methods are simpler than the conventional method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.