Abstract

The ITER Toroidal Field (TF) coil winding packs are designed to be wound in double-pancakes. The twin-box joint provides the electrical pancake-to-pancake connection between the two Nb3Sn 68kA conductors and electrical coil-to-bus bar connection between the TF coil terminations and NbTi 68kA bus bars conductors.The twin-box full size joint sample connecting two Nb3Sn conductors (pancake-to-pancake joint) was prepared in order to qualify the TF joint assembly in SULTAN Test Facility. The original goal of the test program was the measurement of joint resistance at different operating conditions. The accidental dump of the SULTAN background field caused a noticeable increase of resistance due to the induced electromagnetic transient load. The TF joint test was continued in order to investigate a change of joint resistance following electromagnetic transient loading which was triggered by intentional dump of the background field. Also, a dependence of the joint resistance on current was observed; in order to explore the origin of resistance change, additional experiments were performed with a modified (artificially degraded) TF twin-box joint.The test results of a TF twin-box joint after electromagnetic transient loading and performance of the joint after a modification are presented in this paper. The performance of Nb3Sn 68kA conductor observed during those tests is highlighted as well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call