Abstract
Polyvinyl acetate (PVAc) was added as a replacement for melamine-formaldehyde (MF) resin in the formaldehyde-based resin system to reduce formaldehyde and volatile organic compound (VOC) emissions from the adhesives used between plywoods and fancy veneers. A variety of techniques, including 20-l chamber, field and laboratory emission cell (FLEC), VOC analyzer and standard formaldehyde emission test (desiccator method), were used to determine the formaldehyde and VOC emissions from engineered flooring bonded with five different MF resin and PVAc blends at MF/PVAc ratios of 100:0, 70:30, 50:50, 30:70 and 0:100. Although urea-formaldehyde (UF) resin had the highest formaldehyde emission, the emission as determined by desiccator method was reduced by exchanging with MF resin. Furthermore, the formaldehyde emission level was decreased with increasing addition of PVAc as the replacement for MF resin. UF resin in the case of beech was over 5.0 mg/l, which exceeded E2 (1.5-5.0 mg/l) grade. However, MF30:PVAc70 was <or=E1 (below 1.5 mg/l) grade. Because formaldehyde emission is caused by formaldehyde-based resin, the engineered floorings bonded with PVAc only had emissions of just 0.25 mg/l. The results of formaldehyde emission by the 20-l small-chamber and FLEC methods showed a similar tendency with those from the desiccator method. After the replacement of UF resin by MF resin, PVAc addition further reduced formaldehyde emission. With increasing installation time, formaldehyde emission factors (EFs) were decreased. Furthermore, the results of the desiccator method correlated with those of the 20-l chamber and FLEC methods. VOC emission results by 20-l small-chamber and FLEC methods were similar to the formaldehyde and aldehyde emission results. VOCs were calculated between C6 and C16 as total VOC (TVOC). The TVOC EF results by 20-l small-chamber and FLEC methods were comparable with that of formaldehyde emission by FLEC. Although the major emitted harmful gas from wood-based composites was formaldehyde, it was followed by VOC emission. Although it was hard to compare directly the 20-l chamber and FLEC results because the data were based on the sum of only four VOC compounds, the VOC analyzer can be applied as a pre-test method for TVOC emission test. The TVOC emission results were also similar to the FLEC results. Due to its good correlation with the TVOC emission levels obtained from the standard desiccator, FLEC and 20-l chamber methods, the VOC analyzer can be successfully applied to the measurement of TVOC emissions from adhesives used in building materials. This paper presents TVOC and formaldehyde emission behaviors from the engineered floorings that used in Korean housing recently. To reduce emissions, MF/PVAc hybrid resins were used as bonding material. Normally, TVOC and formaldehyde emissions in indoor conditions are caused by interior materials. The results explained 'materials control' of interior materials are the first way to improve indoor air quality. There is a need to study about environmental-friendly materials for solving indoor air quality problem.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.