Abstract
Estimation of turbulent noise level with L-weighting and A-weighting functions was proposed to a centrifugal fan without scroll casing. The validity of these formulae was examined experimentally in respect to the effects of parameters ; inlet/outlet area ratio of impeller and five fan types. The agreement between the measured and the predicted values of the width of wake and the mean relative velocity was satisfactory. Moreover the experimental values of the overall turbulent noise with L-weighting and A-weighting functions agreed well with the predicted values. Finally, the effects of slip factor and the inlet/outlet area ratio of the impeller on the relative velocity, the width of wake, the sound pressure level and the specific noise level are shown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.