Abstract
The flow rate measurements are the most difficult part of efficiency tests on prototype hydraulic turbines. Among the numerous flow rate measurement methods, the Winter Kennedy method is preferred for measuring turbine flow rates, since it is convenient, practical and economical. This paper describes efficiency tests on a large 300 MW Francis turbine, with the flow rate measured using the Winter Kennedy method and the Winter Kennedy flow rate coefficient calibrated using the Gibson method. The measured turbine efficiency curve is then compared with the curve provided by the manufacturer. The CFD calculations including the spiral case are then used to analyze the influence with the coefficient K and index n in the Winter Kennedy flow rate formula on the flow rate measurement. The uncertainty values of n and K are a key reason for the differences between the curves obtained from the efficiency test and the curves provided by the manufacturer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.