Abstract
In this research work, it has been reported a ratiometric fluorescent sensor based on tungsten disulfide quantum dots (WS2 QDs) and fluorescein for the determination of Cefixime (CEF). When excited by radiation of 400 nm wavelength the probe illustrates dual emissions centered at 460 nm and 510 nm. CEF quenches the fluorescence (FL) intensity of fluorescein (510 nm), while it doesn't affect the FL emission of WS2 QDs at 460 nm. The change in the ratio of the two peaks (F460/F510) of the prepared sensor (WS2 QDs/fluorescein) is linearly proportional to the CEF concentration in the range of 200–2.500 ng/mL with a limit of detection (LOD) of 45 ng/mL. Hence, the proposed probe can be successfully used for CEF quantification in the milk samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.