Abstract

A 62-year old male patient underwent uneventful internal fixation of a sub-capital hip fracture four years previously. Due to aseptic necrosis of the femoral head, the screws were removed. Biopsy demonstrated caseous material and cultures were sterile. Six weeks later, when the patient was re-admitted for total hip replacement, tubercular infection of the hip was apparent. This case describes a queiscent tubercular infection of the hip joint complicating internal fixation of a hip fracture. The infection was activated following hardware removal. To our knowledge this is the first described case of tubercular infection complicating internal fixation of the hip.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.