Abstract
In the previous paper, we showed that a circular plate with many small holes attached just downstream of the outlet of the feed water pipe is a better device for controlling the distribution of the flow rate into the branch tubes from a header in a multitube heat exchanger. It was also reported that the flow rate distribution in the case with a particular hole diameter is remarkably different from that with the other diameter. In the present experiment, to clarify the mechanism to cause the difference, the flow pattern in the header was visualized by using aluminum powder as a tracer, and the pressure distribution on the bottom wall of the header was measured. The results show that the flow rate distribution is closely related to the flow pattern in the header.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.