Abstract

PurposeThe purpose of this study was to compare alignment measured on standard anteroposterior (AP) radiographs versus full-length weight-bearing radiographs.MethodsPatients were prospectively enrolled from June 2019 to August 2019 from a single orthopedic surgeon’s practice if they were ≥ 18 years of age, obtained both AP and full-length alignment radiographs and were capable of full weight-bearing with appropriate positioning. Patients were excluded if they were < 18 years of age, had previous knee arthroplasty, previous knee or hip osteotomy, were unable to bear full weight on both limbs, and if the patient’s body habitus precluded appropriate visualization of necessary landmarks on the radiographs. Tibiofemoral angles were measured on AP radiographs using 2 techniques (AP angles 1 and 2). Linear regression and paired t tests were used to compare measurements. The minimal clinically important difference was defined as < 2°.ResultsThere were 120 patients (62 males, 58 females) with an average age of 45 ± 17 years who were enrolled. There were positive correlations between average alignment on full-length weight-bearing and AP radiographs for AP angle 1 (r = 0.72) and AP angle 2 (r = 0.76) measurement techniques (P < .001). There was a significant difference in mean alignment between full-length weight-bearing and AP measurements (AP angle 1: 2.5° difference; AP angle 2: 4.4° difference; P < .001). Frequency distributions for the minimal clinically important difference between true mechanical alignment and AP views demonstrated that 46.7% of patients had ≥ 2° difference for AP angle 1, and 78.3% of patients had ≥ 2° difference for AP angle 2.ConclusionThe average absolute difference in alignment measured between standard AP radiograph and full-length weight-bearing radiograph views was significant, with 46.7% to 78.3% of patients having a greater than 2° absolute difference between these 2 views. In cases where precise objective alignment measurement is necessary, full-length weight-bearing radiographs are recommended over standard AP radiographs for presurgical planning so as to reduce potential error in over- or underestimation of the true mechanical alignment.Study DesignProspective case-comparison; Level of evidence, 1.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.