Abstract
The experimental assessment of the actual reactor hydrodynamic behavior is aimed at detecting possible deviations from the design configuration, as well as suggesting corrective/improving modifications, efficacy of which can be also assessed in the aftermath. The hydrodynamic scheme can be defined by means of tracer tests (stimulus–response method) used for detecting the residence time distribution curve. This study shows the results of three hydrodynamic tests performed on a wastewater treatment plant half-line, in which a biological process (denitrification and oxidation–nitrification) is carried out. Hydrodynamic faults (in terms of dead space and/or flow bypass) were identified, and consequent actions suggested (i.e., change in submerged mixers orientation in the reactors; sinking of the final section of the sludge recirculation pipe below the free surface to avoid foaming phenomena; introduction of new mixed liquor recirculation lines). These actions, together with a careful selection of wastes to be treated, led to an improvement of the overall process performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Environmental Science and Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.