Abstract

Introduction and hypothesisThe objective of this study was to report 1 year anatomical and functional outcomes of trocar-guided total tension-free vaginal mesh (Prolift™) repair for post-hysterectomy vaginal vault prolapse with one continuous piece of polypropylene mesh.MethodsWe conducted a prospective observational cohort study of 46 patients. A minimum sample size of 35 patients was needed to detect a recurrence rate of less than 20% at 12 months. Instruments of measurement used were pelvic organ prolapse quantification and validated questionnaires.ResultsOverall anatomical success was 91% (95% confidence interval 83–99), with significant improvement in experienced bother and quality of life. Mesh exposure occurred in seven patients (15%). No adverse effects on sexual function could be detected.ConclusionsTrocar-guided total tension-free vaginal mesh (Prolift™) repair with one continuous piece of mesh for post-hysterectomy vaginal vault prolapse is well tolerated and anatomically and functionally highly effective. Results of controlled trials will determine its position in the operative armamentarium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.