Abstract

Metals and their alloys are very important for orthopedic applications, and the basic requirements for a successful implant are chemical stability, mechanical behavior, and biocompatibility in body fluids and tissues. For prosthesis applications, the corrosion resistance of metals is one of the major prerequisites to avoid impairment of the material properties due to degradation. The combined action of corrosion and wear on the material is called tribocorrosion and DLC (Diamond-Like Carbon) films have been extensively studied to increase prosthesis biocompatibility and to protect from corrosion. Additionally, DLC coatings can prevent the prosthesis to release toxic elements due to plastic deformation and corrosion. This paper is about tribocorrosion studies on DLC and DLC-Ag (DLC containing silver nanoparticles) on Ti-6Al-4V substrates. These films were obtained by PECVD (Plasma Enhanced Chemical Vapor Deposition) using hexane as a precursor. The tribocorrosion behavior of uncoated and coated samples was investigated in the reciprocating mode in Ringer’s lactate solution. From the polarization test results, the protective efficiency of the film was calculated. Silver nanoparticles improved the corrosion resistance of the films. The protective efficiency was 15 and 19% for DLC and DLC-Ag films, respectively.