Abstract
AbstractThis article discusses the tri‐core photonic crystal microstructure fiber for the process of simultaneous sensing for salinity and temperature of water substances. This kind of microstructure is preferred in many sensing application to scale the detection process in micrometer range. In this novel sensor, the sensitivity is calculated through coupling mechanism by tracking wavelength shift of various concentrations of salinity and temperature using finite element method. The sensible samples are in liquid and are infiltrated into the framed hollow cavity. Based on the coupling principle between silica substrate and the analyte material, the sense of the salt as well as temperature is obtained. Finally, it is noted that sensitivity of the salt level in water as 5404.9 nm/RIU for x polarization direction and 5674 nm/RIU for y polarization direction have been calculated with the temperature sensitivity of 4 nm/°C in the same water substances.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.