Abstract
Study DesignRetrospective review.PurposeTo identify the trends in stimulator use, pair those trends with various grafting materials, and determine the influence of stimulators on the risk of revision surgery.Overview of LiteratureA large number of studies has reported beneficial effects of electromagnetic energy in healing long bone fractures. However, there are few clinical studies regarding the use of electrical stimulators in spinal fusion.MethodsWe used insurance billing codes to identify patients with lumbar disc degeneration who underwent anterior lumbar interbody fusion (ALIF). Comparisons between patients who did and did not receive electrical stimulators following surgery were performed using logistic regression analysis, chi-square test, and odds ratio (OR) analysis.ResultsApproximately 19% of the patients (495/2,613) received external stimulators following ALIF surgery. There was a slight increase in stimulator use from 2008 to 2014 (multi-level R2=0.08, single-level R2=0.05). Patients who underwent multi-level procedures were more likely to receive stimulators than patients who underwent single-level procedures (p<0.05; OR, 3.72; 95% confidence interval, 3.02–4.57). Grafting options associated with most frequent stimulator use were bone marrow aspirates (BMA) plus autograft or allograft for single-level and allograft alone for multi-level procedures. In both cohorts, patients treated with bone morphogenetic proteins were least likely to receive electrical stimulators (p<0.05). Patients who received stimulation generally had higher reimbursements. Concurrent posterior lumbar fusion (PLF) (ALIF+PLF) increased the likelihood of receiving stimulators (p<0.05). Patients who received electrical stimulators had similar revision rates as those who did not receive stimulation (p>0.05), except those in the multilevel ALIF+PLF cohort, wherein the patients who underwent stimulation had higher rates of revision surgery.Conclusions Concurrent PLF or multi-level procedures increased patients’ likelihood of receiving stimulators, however, the presence of comorbidities did not. Patients who received BMA plus autograft or allograft were more likely to receive stimulation. Patients with and without bone stimulators had similar rates of revision surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.