Abstract

This report presents studies on the seismic response of high-rise RC buildings in Japan. Data concerning the seismic response of approximately 600 high-rise RC buildings constructed from 1972 to 2015 were collected. Seismic response characteristics were analyzed by focusing on differences in seismic resistant structures, seismic response control structures, and seismic isolation structures. The results indicated that the maximum story drift ratio response under the level 1 study seismic ground motion (R) and the level 2 study seismic ground motion (R) criteria is smaller for seismic isolation structures than that of the seismic resistant structure and seismic response control structures. In addition, focusing on the R-R relationship, the correlation is low in the seismic resistant and seismic response control structures, but is almost linear in the seismic isolation structure. This is because the seismic isolation structure is designed such that the superstructure does not become plastic even with level 2 seismic ground motion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.