Abstract

A method using three-dimensional electrode is applied to treat wastewater in oil fields, which contains polyacrylamide (PAM), for analogue. A best condition for electrolysis (I = 1.0 A, t=90 min, c=0.1%, m=980 g, ϕ=5 mm, d=5.0 cm) has been determined, under which the COD removal efficiency reached 96.0%, COD containing in wastewater reduced to 64.3 mg/L from 1 622.9 mg/L, the figure before treatment. Three categories of PAM-containing wastewater in production practice have been treated with the COD removal ratios being 87.5%, 82.4% and 84.7% respectively. Presence of H2O2 and ·OH are detected by means of Ti(IV)-5-Br-PADAP technique and colorimetry respectively. The concentration is positively proportional to the COD removal ratio and increases in accordance with increment of time of electrolysis and current.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call