Abstract
We prospectively studied 20 patients whose selected unstable tibial diaphyseal fractures were treated with the combined techniques of minimal internal fixation and external fixation. Five fractures were closed and 15 were open (six Grades I and II, nine Grade III). Seventeen were due to high-energy injuries. The minimum followup was 2 years. All fractures healed, one with malalignment. Time to union averaged 12 weeks in closed fractures and 19 weeks in open fractures. All high-energy fractures underwent bone grafting. The external fixation was removed by dynamization. Thirteen complications occurred in nine patients, all with open fractures. Three of 120 pins became infected (2.5%). Early bone grafting and dynamization of the external fixation prevented the malunions and nonunions reported previously with this technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.