Abstract

Background. Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures.Purpose. To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate.Patients and methods. A retrospective review was conducted of patients from one institution using the volar locking plate to treat intra-articular and extra-articular distal radius fractures. Unstable distal radius fractures in 15 patients, comprising 3 men and 12 women with a mean age of 64.4 years (34–76 years), were treated with a volar locking compression plate (Acu-Loc distal radius plate system; Acumed, Oregon, USA) and followed up for a minimum of 1 year. Fractures were classified using the AO classification. Radiographic parameters of preoperative, postoperative, and final follow-up radiographs were compared. The time to initiation of active range of motion was determined. Final follow-up range of motion and complications were reported.Results. At final functional assessment, the scores of 5 patients were excellent, 7 patients good, and 3 patients fair according to Cooney's Clinical Scoring Chart. No non-union or infection occurred. Rupture of the flexor pollicis longus tendon occurred in 1 patient.Conclusion. Treatment of unstable distal radius fractures with a volar locking plate leads to satisfactory results, provided the operative technique is carefully performed to prevent complications.

Highlights

  • Open reduction and internal fixation using an interlocking plate system is a valid treatment of displaced extra-articular and intra-articular distal radius fractures in adults [1,2,3,4]

  • A retrospective review was conducted of patients from one institution using the volar locking plate to treat intra-articular and extra-articular distal radius fractures

  • Treatment of unstable distal radius fractures with a volar locking plate leads to satisfactory results, provided the operative technique is carefully performed to prevent complications

Read more

Summary

Introduction

Open reduction and internal fixation using an interlocking plate system is a valid treatment of displaced extra-articular and intra-articular distal radius fractures in adults [1,2,3,4]. To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate. A retrospective review was conducted of patients from one institution using the volar locking plate to treat intra-articular and extra-articular distal radius fractures. Treatment of unstable distal radius fractures with a volar locking plate leads to satisfactory results, provided the operative technique is carefully performed to prevent complications

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call