Abstract

To collect fundamental data for the improvement of drinking water quality, focusing on the removal of 2-MIB, Geosmin, IPMP, IBMP and TCA, a total of 20m3/d pilot plant was operated with process schemes of GAC with post-O3(PP-I), and without ozonation(PP-II). Five taste and odor causing substances could be removed to non-detectable concentration with PP-I, but GAC alone was not so effective as PP-I. The larger the EBCT and Iodine Number of GAC column employed, the higher the removal efficiencies expected. The minimum EBCT and Iodine Number were respectively 15 min and 1,000 mg/g of GAC column. Geosmin removal efficiencies ranged 30 to 40% at 15.6 ng/l during conventional process scheme, but 70 to 80% removal was achieved by the PP-I and 60 to 70% by PP-II was achieved. IPMP removal efficiencies were 60 to 80% with GAC only. IBMP and TCA were seldom detected in raw water samples, but TCA was the most difficult to remove of five taste and odor causing substances.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.