Abstract

In this work the treatment of leachate originating from an old landfill was compared using a variety of methods both singularly and in combination. Aerobic biological treatment gave a COD removal ranging from 32–35%, but it was very effective for BOD and ammonia removal (97% and 99%, respectively). By using chemical oxidation a COD reduction up to 33% was achieved. The application of chemical precipitation gave a COD removal in the range of 36–42%. The combination of biological and chemical oxidation, biological oxidation and chemical precipitation or chemical oxidation and chemical precipitation, led to a COD reduction up to 57%. The best results were obtained when a biological oxidation was applied in two stages combination with chemical oxidation and chemical precipitation reducing COD concentration values up to 87%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.