Abstract

Severe stress urinary incontinence (SUI) is usually treated by the implant of artificial sphincter positioned around bulbar urethra. AdVance sling is a functional, non-obstructive, anti-incontinence device that showed good results especially for mild and moderate SUI. We present our experience with AdVance sling in 7 patients with severe SUI unfit for artificial sphincter. Our results, after a follow-up of more than 6 months, showed a continence rate of 28% and an improvement rate of 43%, while 2 patients did not show any benefit. The success of AdVance sling depends on the integrity of urethral sphincter and can be applied also in selected cases for the treatment of severe post-prostatectomy stress urinary incontinence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.