Abstract

This study aims to treat patients with preterm premature rupture of the membranes (PPROM) and anhydramnion using continuous amnioinfusion through a subcutaneously implanted port system. An amniotic fluid replacement port system was implanted in seven patients with PPROM and anhydramnion starting at the 20th week of gestation (range, 14-26 weeks) for long-term amnioinfusion. Saline solutions (2 L/day; Jonosteril(®), Sterofundin(®), isotonic NaCl 0.9% solution, lactated Ringer's solution) and a hypotonic aqueous composition with reduced chloride content similar to the electrolyte concentration of human amniotic fluid were used for the continuous amnioinfusion. The mean duration of the PPROM delivery interval continued for 49 days (range, 9-69 days), with 3 weeks of amnioinfusion via the port system (range, 4-49). The newborns showed no signs of lung hypoplasia. Long-term lavage of the amniotic cavity via a subcutaneously implanted port system in patients with PPROM and anhydramnion may help prolong the pregnancy and avoid fetal lung hypoplasia. A hypotonic aqueous composition with reduced chloride content similar to human amniotic fluid can be safely used for amnioinfusion. Prospective randomized studies are ongoing.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call