A randomized, prospective study comparing Ender nailing with external fixation for open fractures of sixty-three tibiae (sixty patients) was undertaken. Ender nailing proved to be at least as effective as external fixation with respect to seven parameters: time to union, tibial alignment, total number of operations, ranges of motion of the knee and ankle, pain, presence of infection, and complications. Ender nailing is a safe alternative to external fixation for grade-I and grade-II open fractures. It should not be used for comminuted fractures, which might shorten about the nails.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.