Abstract
An integrated membrane bioreactor (MBR) with synthetic RO membrane cleaning wastewater from a thermal power plant was used to study the long-term operating characteristics, membrane fouling, and cleaning of membrane fouling. The results show that the MBR had a great removal effect on mainly an organic pollutant (citric acid) with an average of 98.4% rejection, and the concentration of organics in the effluent also achieved “Discharge standard of pollutants for municipal wastewater treatment plant” (GB12/599-2015). The optimal operating conditions were as follows: the membrane flux was 8 L/(m2·h); the hydraulic retention time (HRT) was 4 h; the sludge retention time (SRT) was 15 d, and the pH value was 6~7. A membrane fouling analysis showed that the resistance of the cake layer and the concentration polarization were the main components of membrane fouling. When the specific flux (SF) decreased to 10 L/(h·m2 mH2O), the membrane module was cleaned by tap water and then soaked in 0.05 wt% hydrochloric acid (HCl) and 3000 mg/L sodium hypochlorite (NaOCl) for 1 h and 3 h, respectively. Finally, the membrane flux could be recovered to 84.9% compared to the new membrane.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.