Abstract
Membrane technology has been proved as an effective technology in the treatment of low level radioactive wastewaters (LLRWs). As ‘loose reverse osmosis’, nanofiltration can be integrated with RO and offers the high permeate flux at low pressure without obvious loss of decontamination efficiency. In the paper, three kinds of commercially available NF membrane materials were investigated by lab-scale experiment with respect to the nuclide rejection. The results demonstrate the efficient elimination. The membrane flux can be improved by the elevation of temperature and cross-flow velocity within the ranges of 20–30°C and 0.4–1.0ms−1. The radiation resistance test demonstrates no obvious loss of flux and nuclide rejection after a long term operation in the radioactive circumstance. A brief comparison of LLRWs treatment methods shows that NF can perform the pre-treatment of RO and optimize the entire membrane system with high flux and low pressure. In the paper, decontamination factor and flux values of the tested membranes at different operation condition are summarized as the reference for membrane selection and system design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.