Abstract

The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation. Our aim was to analyze the outcomes after treatment with braided stents. A systematic search of 3 databases was performed for studies published from 2006 to 2017. According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents. Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes. Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis. Successful stent delivery and complete aneurysm occlusion were 97% (1041/1095; 95% CI, 95%-98%) (I2 = 44%) and 88.3% (1097/1256; 95% CI, 85%-91%) (I2 = 72%), respectively. Overall, treatment-related complications were 7.4% (107/1317; 95% CI, 5%-9%) (I2 = 44%). Ischemic/thromboembolic events (48/1324 = 2.4%; 95% CI, 1.5%-3.4%) (I2 = 27%) and in-stent thrombosis (35/1324 = 1.5%; 95% CI, 0.6%-1.7%) (I2 = 0%) were the most common complications. Treatment-related morbidity was 1.5% (30/1324; 95% CI, 0.9%-2%) and was comparable between the LEO and LVIS groups. Complication rates between the anterior (29/322 = 8.8%; 95% CI, 3.4%-12%) (I2 = 41%) versus posterior circulation (10/84 = 10.5%; 95% CI, 4%-16%) (I2 = 0%) and distal (30/303 = 8%; 95% CI, 4.5%-12%) (I2 = 48%) versus proximal aneurysms (14/153 = 9%; 95% CI, 3%-13%) (I2 = 46%) were comparable (P > .05). Limitations were selection and publication biases. In this analysis, treatment with the LEO and LVIS stents was relatively safe and effective. The most common complications were periprocedural thromboembolisms and in-stent thrombosis. The rate of complications was comparable among anterior and posterior circulation aneurysms, as well as for proximal and distally located lesions.

Highlights

  • The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation.PURPOSE: Our aim was to analyze the outcomes after treatment with braided stents.DATA SOURCES: A systematic search of 3 databases was performed for studies published from 2006 to 2017.STUDY SELECTION: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents.DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes.DATA SYNTHESIS: Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis

  • The third generation of self-expandable closed stents was produced by braiding individual strands of nitinol onto a mandrel (LVIS, MicroVention, Tustin, California; and LEO, Balt Extrusion, Montmorency, France).[4,5]

  • A total of 35 studies and 1426 patients with 1518 intracranial aneurysms treated with LEO or LVIS stents were included in our review

Read more

Summary

Introduction

The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation.PURPOSE: Our aim was to analyze the outcomes after treatment with braided stents.DATA SOURCES: A systematic search of 3 databases was performed for studies published from 2006 to 2017.STUDY SELECTION: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents.DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes.DATA SYNTHESIS: Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis. The safety and efficacy of treatment with self-expandable braided stents (LEO and LVIS) required further investigation. PURPOSE: Our aim was to analyze the outcomes after treatment with braided stents. STUDY SELECTION: According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we included studies reporting patients treated with LEO or LVIS stents. DATA ANALYSIS: Random-effects meta-analysis was used to pool the following: aneurysm occlusion rate, complications, and neurologic outcomes. DATA SYNTHESIS: Thirty-five studies evaluating 1426 patients treated with braided stents were included in this meta-analysis. Treatment-related morbidity was 1.5% (30/1324; 95% CI, 0.9%–2%) and was comparable between the LEO and LVIS groups. Complication rates between the anterior (29/322 ϭ 8.8%; 95% CI, 3.4%–12%) (I2 ϭ 41%) versus posterior circulation (10/84 ϭ 10.5%; 95% CI, 4%–16%) (I2 ϭ 0%) and distal (30/303 ϭ 8%; 95% CI, 4.5%–12%) (I2 ϭ 48%) versus proximal aneurysms (14/153 ϭ 9%; 95% CI, 3%–13%) (I2 ϭ 46%) were comparable (P Ͼ .05)

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.