Abstract

The management of symptomatic articular cartilage lesions, especially in the young, fit individual remains an area of considerable controversy. Articular cartilage repair or reconstruction techniques may offer these patients alternatives to arthroplasty. The TruFit™ plug is a synthetic biphasic polymer scaffold that is designed for implantation at the site of a focal chondral defect. The aim of this study is to report the long-term clinical and radiological outcomes of patients treated with the TruFit™ plug for chondral defects within the knee. 11 patients underwent TruFit™ plug implantation. Long-term outcome scores were available for 6 patients at a mean follow up of 121 months (SD 12.0 months, 1 patient unavailable and 4 excluded after arthroplasty surgery). There was no statistically significant improvements in any score although all scores did improve. At a mean radiographic follow up of 70 months (17–113) of 9 patients, the mean MOCART score was 22.2 (SD 15.6). All patients had incomplete or no evidence of plug incorporation and persistent chondral loss. Based on these results, we do not recommend the use of the TruFit™ plug.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.