Abstract
The TOBA (Tack Optimized Balloon Angioplasty) II trial is a prospective, single-arm, multicenter study that investigated Tack treatment for patients with dissection after angioplasty in the superficial femoral artery and/or proximal popliteal artery. The Tack device is a nitinol-based, short (6mm), stent-like implant with low outward force that can be deployed in a targeted fashion to treat vascular dissection. TOBA II primary results through 12 months have been published previously. This report provides follow-up safety and efficacy results through 24 months (RC). The TOBA II trial enrolled 213 patients with Rutherford classification 2 to 4 and a de novo or non-stented restenotic lesion in the superficial femoral artery and/or proximal popliteal artery who developed a dissection of any grade after treatment with plain balloon or drug-coated balloon (DCB) angioplasty. Participants were followed for 30 days, 6 months, 12 months, 24 months, and 36 months following the procedure. Evaluations included clinically driven target lesion revascularization (CD-TLR), ankle-brachial index, Rutherford classification, peripheral artery questionnaire, quality of life assessed by the EQ-5D-3L, and the Walking Impairment Questionnaire. At enrollment, mean age was 68.2 ± 9.1 years, 70.9% were male, and 95.8% of patients were categorized as RC 2 or 3. The distribution of balloon types in the study were standard balloons: 42.3%; and drug-coated balloons: 57.7%. At 24-month follow-up, 167 patients (78.4%) had available data. The overall survival rate at 24 months was 95.4% and there were no major amputations during this time. After 24 months of follow-up, the Kaplan-Meier freedom from CD-TLR was 77.7%. Rutherford classification, ankle-brachial index, and quality of life were significantly improved compared with baseline through 24 months. The TOBA II 24-month data demonstrate durable intermediate-term outcomes with the use of the Tack Endovascular System. Tack deployment was a safe and effective therapeutic option for dissection repair following angioplasty.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.