Abstract

Reverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155° and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135° in combination with a 4mm lateralized glenosphere in context of cuff tear arthropathy. For this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m = 11, f = 10; mean age 76years; mean follow-up 42months) were treated with a standard 155° humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m = 5, f = 16; mean age 72years; mean follow-up 34months) were treated with a 135° humeral component and 4mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. The clinical results were similar in both groups concerning the Constant Score (group A = 56.3 vs. group B = 56.1; p = 0.733), the adjusted CS (group A = 70.4% vs. group B = 68.3%; p = 0.589) and the SSV (group A = 72.0% vs. group B = 75.2%; p = 0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction = 98° versus 97.9°, p = 0.655; external rotation with the arm at side = 17.9° versus 18.7°, p = 0.703; external rotation with the arm positioned in 90° of abduction = 22.3° versus 24.7°, p = 0.524; forward flexion = 116.1° versus 116.7°, p = 0.760. The rate of scapular notching was higher (p = 0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A = 48% vs. group B = 38%). Theoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155° and a standard glenosphere, implants with a humeral inclination angle of 135° and a 4mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching. Level III, retrospective comparative study.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call