Abstract

BackgroundWhile some traumatic closed index extensor tendon ruptures at the musclotendinous junction have been previously reported, closed index extensor tendon pseudorupture due to intertendinous attenuation is exceedingly rare with only one case report of a gymnastics-related sports injury in the English literature. Herein, we report two non-sports injury related cases of traumatic index extensor tendon attenuation mimicking closed tendon rupture, including the pathological findings and intraoperative video of the attenuated extensor indicis proprius tendon.Case presentationA 28-year-old man and a 30-year-old man caught their hands in a high-speed drill and lathe, respectively, which caused a sudden forced flexion of their wrists. They could not actively extend the metacarpophalangeal joints of their index fingers. Intraoperatively, although the extensor indicis proprius and index extensor digitorum communes tendons were in continuity without ruptures, both tendons were attenuated and stretched. The attenuated index extensor tendons were reconstructed either with shortening by plication or step-cut when the tendon damage was less severe or, in severely attenuated tendons, with tendon grafting (ipsilateral palmaris longus) or tendon transfer. Six months after the operation, the active extension of the index metacarpophalangeal joints had recovered well.ConclusionsTwo cases of traumatic index extensor tendon attenuation were treated successfully by shortening the attenuated tendon in combination with tendon graft or transfer. We recommend WALANT (wide-awake local anesthesia and no tourniquet) in the reconstruction surgery of index extensor tendon attenuation to determine the appropriate amount of tendon shortening or optimal tension for tendon grafting or transfer. Intraoperative voluntary finger movement is essential, as it is otherwise difficult to judge the stretch length of intratendinous elongation and extent of traumatic intramuscular damage affecting tendon excursion.

Highlights

  • While some traumatic closed index extensor tendon ruptures at the musclotendinous junction have been previously reported, closed index extensor tendon pseudorupture due to intertendinous attenuation is exceedingly rare with only one case report of a gymnastics-related sports injury in the English literature

  • Traumatic closed extensor tendon rupture of the index finger alone is uncommon and in previous reports has typically occurred at the musclotendinous junction [1,2,3,4,5]

  • The extensor indicis proprius (EIP) tendon attenuation might occur when 4 to 8% strain force is created by catching the index finger in the high-speed drill or lathe

Read more

Summary

Conclusions

Two cases of traumatic index extensor tendon attenuation were treated successfully by shortening the attenuated tendon in combination with tendon graft or transfer. We recommend WALANT (wide-awake local anesthesia and no tourniquet) in the reconstruction surgery of index extensor tendon attenuation to determine the appropriate amount of tendon shortening or optimal tension for tendon grafting or transfer. Intraoperative voluntary finger movement is essential, as it is otherwise difficult to judge the stretch length of intratendinous elongation and extent of traumatic intramuscular damage affecting tendon excursion

Findings
Background
Discussion and conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call