Abstract

IntroductionCurrently, polypropylene materials are used widely for the treatment of various urogynecologic disorders. This type of treatment can be complicated, although rarely, with erosions of the polypropylene implants into the bladder or the urethra. There is no established treatment for such complications. We present our experience in transvesical laparoendoscopic single-site surgery (T-LESS) removal of eroded materials, and a review of the literature in this field.Materials and methodsFrom June 2015 to May 2017 eight females, with an average age of 66.5 years (range 55–80 years), were referred to our Center because of the erosion of polypropylene material in the bladder, after anti-incontinence or pelvic organ prolapse treatment. Patients were diagnosed with ultrasound and cystoscopy. Seven bladder erosions and one bladder and urethral penetration were found. Patients were qualified for removal with the T-LESS approach. The Tri-Port + disposable set and standard laparoscopic instruments were used. The eroded materials were dissected and cut away, and the defects of the bladder wall were closed with barbed sutures. The peri-operative efficacy and safety of the method were assessed, and the patients were scheduled for follow-up visits at 6 weeks and every 3 months thereafter. The patients were offered a cystoscopic exam during the 7–10 month period after the operation.ResultsThe procedures were completed successfully in all patients. No blood loss or complications were observed. The mean operative time was 54.5 min, and the average hospital stay was 30 h. During a follow-up at 11 months, all patients were cured, except for one who presented urethral erosion.ConclusionsThe T-LESS technique for removal of eroded meshes is a safe and effective method. The precise access to the bladder minimizes morbidity, and suturing the bladder wall defects may reduce the risk of recurrence.

Highlights

  • Polypropylene materials are used widely for the treatment of various urogynecologic disorders

  • The use of polypropylene materials has been a standard treatment for stress urinary incontinence and pelvic organ prolapse since 1995, when Ulmsten and Petros introduced a fabric TVT tape to perform mid-urethral placement of a sling

  • We present our clinical results in eight patients undergoing surgery using the transvesical, laparoendoscopic, singlesite surgery (T-LESS) to remove surgical materials that had eroded into the bladder

Read more

Summary

Introduction

Polypropylene materials are used widely for the treatment of various urogynecologic disorders This type of treatment can be complicated, rarely, with erosions of the polypropylene implants into the bladder or the urethra. The use of polypropylene materials has been a standard treatment for stress urinary incontinence and pelvic organ prolapse since 1995, when Ulmsten and Petros introduced a fabric TVT tape to perform mid-urethral placement of a sling. This revolutionized urinary incontinence therapy [1]. The biggest challenge among the complications is bladder erosions resulting from not following the gold standard for repair surgery, and the relapse of the disease.

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call