Abstract

Introduction. Spontaneous nasal liquorrhea is a pathological condition associated with defect between nasal cavity and intracranial structures that lead to the expiration of the CSF from the nasal cavity.The objective is to evaluate the effectiveness of endoscopic endonasal approach in the CSF leak treatment.Material and methods. For the period from 2008 to 2018, 38 patients with spontaneous nasal liquorrhea were examined and treated in Pavlov First Saint Petersburg State Medical University, the clinic of neurosurgery of Kirov Medical Institute and Almazov National Medical Research Centre. All patients underwent plastic surgery of the CSF fistula by endoscopic endonasal aproach.Results. Only in 4 cases, there was a large defect, the failure of the closure of which required repeated surgical intervention in 1–2 weeks after the initial operation.Conclusion. The use of autologous tissues (muscle or fat autograft) is the method of choice for repeated surgical plastics of the cerebrospinal fluid fistula or in a large size defect (more than 5 mm).

Highlights

  • Spontaneous nasal liquorrhea is a pathological condition associated with defect between nasal cavity and intracranial structures that lead to the expiration of the cerebrospinal fluid (CSF) from the nasal cavity

  • The OBJECTIVE is to evaluate the effectiveness of endoscopic endonasal approach in the CSF leak treatment

  • Наиболее надежным лоскутом для закрытия дефекта является тканевой аутотрансплантат, в нашем случае – жировой трансплантат, который помещается в зону ликворного свища

Read more

Summary

Introduction

Spontaneous nasal liquorrhea is a pathological condition associated with defect between nasal cavity and intracranial structures that lead to the expiration of the CSF from the nasal cavity. Transsphenoidal endoscopic approach in the treatment of spontaneous cerebrospinal fluid (CSF) leak Vladislav Y. The use of autologous tissues (muscle or fat autograft) is the method of choice for repeated surgical plastics of the cerebrospinal fluid fistula or in a large size defect (more than 5 mm). A. Transsphenoidal endoscopic appro­ ach in the treatment of spontaneous cerebrospinal fluid (CSF) leak.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.