Abstract

A method for transscleral fixation of silicone plate haptic posterior chamber intraocular lenses (PC IOLs) via the pars plana is described. One 10-0 polypropylene transscleral suture passed through the sclera and the PC IOL hole and a similar suture passed through the sclera only were withdrawn outside the eye thorough the pars plana and tied together. Pulling up the scleral end of one suture placed the PC IOL haptic in the sulcus and the knot was pulled outside the eye. Perfluorocarbon liquid was used during the procedure to safely manipulate the PC IOL. The PC IOL was well centered at 3 months of follow-up. Posteriorly dislocated silicone plate haptic PC IOLs can be safely sutured to the sclera via the pars plana by this method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.