Abstract

We present a case where we repaired the aortic arch, by the transposition of the left carotid artery to the ascending aorta. A 52-year-old man presented to our department with a penetrating chest wound by a gunshot in the attempt of suicide. The aortic arch and the insertion of the left carotid artery were involved in the lesion. Through sternotomic approach, the aortic arch was repaired in extracorporeal circulation. Left carotid artery was transected to allow easier repair of the arch posterior wall involved in the lesion, and to reduce the danger of residual stenosis. Then, it was translocated to the ascending aorta by interposing a 7-mm Gore-Tex (W.L. Gore & Associates, Flagstaff, AZ, USA) conduit. The patient complicated renal failure and pneumonia in the postoperative period, but eventually he was discharged in good general conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.