Abstract

BackgroundThis study compared the incidence of deviation along curved canals after preparation with two nickel-titanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe.Material and MethodsForty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Preinstrumentation images were acquired by using a stereomicroscope. The canals were up to an instrument #35/0.04. Postinstrumentation images were captured using the same conditions, and the images were superimposed. The amount of resin removed was measured at 8 different points, beginning at the apical terminus of the canal. Differences in the mesial and distal aspects were measured to evaluate the occurrence of deviation. The Student’s-t test was used for comparison of the intragroup deviation. Intergroup analysis was performed by using one-way ANOVA for each level. For multiple comparisons, the Bonferroni test was used and a cutoff for significance was set at 5%.ResultsIntragroup analysis showed that both instrumentation techniques promoted some deviation at all levels. BT-RaCe showed significantly lower deviation at 0 and 4-mm levels than Group Twisted File Adaptive (p<0.05). On the other hand BT-RaCe showed worse performance at level 6.ConclusionsThe results of this study demonstrated that none of the NiTi tested systems was able to instrument curved canals simulated in resin blocks without some deviation during the preparation. There is still need for improvement in the instruments manufacturing aiming the better performance of endodontic files in curved root canals. Key words:BT-RaCe, Curved root canals, Deviation, Twisted File Adaptive.

Highlights

  • Chemomechanical preparation is intended to promote root canal cleaning, disinfection and shaping

  • To maintain the root canal preparation as centralized as possible, the mechanical property - flexibility - of NiTi systems, enables a curved root canal preparation that is wider in the apical portion, more centered and with fewer deviations [8]

  • Several new endodontic NiTi systems have been developed with different characteristics, such as: crosssectional shape; taper; number and helical angle; kinematics; in addition to changes in metallurgy properties to enhance the mechanical properties of NiTi instruments [7,9,10]

Read more

Summary

Introduction

Chemomechanical preparation is intended to promote root canal cleaning, disinfection and shaping. The aim of this study was to compare the incidence of deviation along simulated curved canals in resin blocks, after instrumentation with TFA and BT-RaCe NiTi rotary systems. This study compared the incidence of deviation along curved canals after preparation with two nickeltitanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe. Material and Methods: Forty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Conclusions: The results of this study demonstrated that none of the NiTi tested systems was able to instrument curved canals simulated in resin blocks without some deviation during the preparation. There is still need for improvement in the instruments manufacturing aiming the better performance of endodontic files in curved root canals

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.