Abstract

We present a transportable ultra-stable clock laser system based on a Fabry-Perot cavity with crystalline Al0.92Ga0.08As/GaAs mirror coatings, fused silica (FS) mirror substrates, and a 20 cm-long ultra-low expansion (ULE) glass spacer with a predicted thermal noise floor of mod σy = 7 × 10-17 in modified Allan deviation at one second averaging time. The cavity has a cylindrical shape and is mounted at 10 points. Its measured sensitivity of the fractional frequency to acceleration for the three Cartesian directions are 2(1) × 10-12 /(ms-2), 3(3) × 10-12 /(ms-2), and 3(1) × 10-12 /(ms-2), which belong to the lowest acceleration sensitivities published for transportable systems. The laser system's instability reaches down to mod σy = 1.6 × 10-16.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.