Abstract
We investigated the characteristics of transport current loss against distorted current with odd-order harmonic component using a Bi2223 short sample conductor. We measured the transport current loss against the distorted current with the 3rd, 5th, or 7th harmonic as a function of the amplitude of each harmonic current. The transport current loss per cycle of fundamental frequency against the distorted current was independent of the fundamental frequency and was compared with the sum of transport current losses against the sinusoidal current with the amplitude of each harmonic current component obtained by Fourier analysis. Fair agreement was obtained in the distorted current with the 3rd harmonic, while a big difference was observed in the distorted current with the 5th or 7th harmonic. Independent of harmonic order, the transport current loss against the distorted current was almost the same as the sum of the transport current losses against the sinusoidal current with the amplitude of the distorted current corresponding to a major hysteresis loop and the amplitude of the small rise and fall of the distorted current corresponding to a minor hysteresis loop that can be directly estimated from the distorted current waveform.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.