Abstract
The resistive type fault current limiter based on YBCO thin film with high critical current density was proposed and developed because of its fast recovery characteristics. We have been developing a magnetic field measurement system with hall sensor to study the critical current density distribution or magnetic properties of high- T c superconductors such as thin film, tape conductor and coated conductors. In this study, the transport current distribution in straight line and U-corner region of meander type resistive fault current limiter using YBCO thin film was investigated experimentally. The both axial and radial self-magnetic field components according to the direct (DC) and alternating (AC) transport currents were measured by two-axis hall probe to estimate the current distribution. And also, the self-magnetic field at the corner of bispiral type fault current limiter was measured by two-axis hall probe with a high spatial resolution to compare with the meander type fault current limiter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.