Abstract

Transport AC loss measurements were performed on several Second Generation (2G) High Temperature Superconducting (HTS) pancake coils. A good agreement was observed between the AC loss values of the coils obtained using two separate techniques. Self-field critical current density of the tape did not have direct effect on the AC losses in coils. Relative orientation of the tapes in 2-tape stack affects AC losses in coils using the stacked conductor. Losses scale with maximum perpendicular field seen by the conductor in the coil suggesting that the magnetization loss is the predominant component of coil losses. Absence of frequency dependence of the losses indicates that the eddy current losses are not significant in the coils up to 400 Hz.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.