Abstract
The objective of this study was to quantify the transmural variation in attenuation for the septal and lateral walls of the heart. Our approach was to utilize a commercially available ultrasonic imaging system to acquire images of excised sections of eight sheep hearts with an orientation similar to that encountered in the apical four-chamber view. The measured values (mean ± SE) of the slope of attenuation for the transmural regions of the septum are: 1.40 ± 0.11, 0.99 ± 0.09, and 1.85 ± 0.16 (dB/cm/MHz) for the left subendocardial, midmyocardial, and right subendocardial zones, respectively. The analogous data from the lateral wall are: 1.42 ± 0.11, 0.83 ± 0.07, and 1.20 ± 0.16 (dB/cm/MHz) for the subendocardial, midmyocardial, and subepicardial zones, respectively. These data demonstrate that ultrasonic attenuation associated with the septum and the lateral wall, when imaged in a manner similar to that of the apical four-chamber view, is anisotropic. (E-mail: jgm@howdy.wustl.edu)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.