Abstract
This paper presents a comparative study of the transmission length (Lt) of pretensioned concrete (PTC) members obtained using experiments and AASHTO, ACI, BIS, Eurocode 2 and fib Model Code (fib-MC) codes. Tests on six PTC specimens (with 12·7 mm dia. strands (ds) and effective prestress (fpe) of 1214 MPa) indicated that Lt can reduce by about 20% when the concrete strength (fci) increases from about 23 to 36 MPa. A case study of the influence of Lt on the shear resistance of a typical precast hollow-core slab showed that the ACI and fib-MC codes provide conservative shear designs, whereas the IS code considers only ds and provides a less conservative design. This paper proposes a revised tentative formula of Lt (as a function of ds, fpe and fci) to be incorporated in the IS 1343 and other codes. It is anticipated that this will lead to more rational and conservative shear designs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.