Abstract

Seven patients (four adults, three children) with discrete subaortic membranous stenosis underwent balloon dilatation using a single or double balloon technique with reduction in systolic gradient across the membrane from 100.42 +/- 19.23 to 29.14 +/- 12.54 mmHg (P less than 0.001). Echocardiography demonstrated thin membranes in all the patients and postprocedure torn fragments could be visualized. The excellent hemodynamic benefits are sustained during 4-24 months follow-up. The results indicate that transluminal balloon dilatation can be a safe and effective treatment for thin subaortic membrane.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call