Abstract

To describe our experience with the use of a novel iodized Polyvinyl Alcohol Polymer liquid agent (Easyx) in type II endoleak treatment with translumbar approach. Our case series is a retrospective review of patients with type II endoleak (T2E) treated with Easyx from December 2017 to December 2020. Indication for treatment was a persistent T2E with an increasing aneurysm sac ≥5 mm on computed tomography angiography (CTA) over a 6-month interval. Technical success was defined as the embolization of the endoleak nidus with reduction or elimination of the T2E on sequent CTA evaluation. Clinical success was defined as an unchanged or decreased aneurysm sac on follow-up CTA. Secondary endpoints included the presence of artifacts in the postprocedural cross-sectional tomographic imaging and post and intraprocedural complications. Ten patients were included in our retrospective analysis. All T2E were successfully embolized. Clinical success was achieved in 9 out of 10 patients (90%). The mean follow-up was 14 3-20 months. No beam hardening artifact was observed in follow-up CT providing unaltered imaging. Easyx is a novel liquid embolic agent with lava-like characteristics and unaltered visibility on subsequent CT examinations. In our initial experience, Easyx showed to have all the efficacy requisites to be an embolization agent for type II EL management. Its efficacy, however, should be evaluated in more extensive studies and eventually compared with other agents.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call