Abstract

We reviewed that clinical courses of 14,550 patients in whom translumbar aortography was performed. The principal aim of the survey was to determine the incidence of major and fatal complications attributable to this diagnostic study, as an index of its safety. We found that in this group, seven major (0.05%) and two fatal (0.014%) complications occurred. The corresponding incidences for transfemoral catheter aortography reported in the literature were found to be 1.34% and 0.06%, respectively. Translumbar aortography, when performed under the proper indications and appropriate conditions, has a degree of safety equal to or greater than that of transfemoral catheter aortography, and its diagnostic reliability within its technical scope is high.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.