Abstract
Due to their low friction index, hip arthroplasties with metal–metal (M–M) friction torque have been an attractive option in young patients with high functional demand, currently they have suffered a decrease in their use due to the complications of some models and physiological reactions adverse reactions related to the elevation of metal ions in the blood. Our objective is to review the patients with M–M pair operated in our centre, correlating the ion level with the position of the acetabular component and with the size of the head. Material and methodsRetrospective review of 166 M–M hip prostheses operated between 2002 and 2011. Sixty five ruled out for different causes (death, loss of follow-up, no current ion control, no radiography or others), leaving a sample of 101 patients to be analysed. Follow-up time, cup inclination angle, blood ion level, Harris Hip Score (HHS), and complications were recorded. ResultsOne hundred and one patients (25 women and 76 men), 55 years of average age (between 26 and 70), of these 8 were surface prostheses and 93 total prostheses. The mean follow-up time was 10 years (between 5 and 17 years). The mean head diameter was 46.25 (between 38 and 56). The mean inclination of the butts was 45.7° (between 26° and 71°). The correlation force between the verticality of the cup and the increase in ions is moderate r=0.31 for Cr and slight r=0.25 for Co. The correlation force between head size and ion increase is weak and inverse r=−0.14 for Cr and r=0.1 for Co. Five patients (4.9%) required revision (2 [1%] due to increased ions with pseudotumor). The mean time to revision was 6.5 years in which the ions increased. The mean HHS was 94.01 (between 55.8 and 100). In the review of patients, we found 3 with a significant increase in ions who had not followed controls, all 3 had an HHS of 100. The angles of the acetabular components were 69°, 60° and 48° and the diameter of the head was 48.42 and 48mm, respectively. Discussion and conclusionsM–M prostheses have been a valid option in patients with high functional demand. A bi-annual analytical follow-up is recommended, since in our case we have detected 3 patients with HHS 100 who presented unacceptable elevation of cobalt >20μm/l (according to SECCA) of the ions and 4 with very abnormal elevation of cobalt ≥10μm/l (according to SECCA), all of them with cup orientation angles >50°. With our review we can conclude that there is a moderate correlation between the verticality of the acetabular component and the increase in blood ions and that the follow-up of this patient with angles >50° is essential.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Revista Espanola de Cirugia Ortopedica y Traumatologia
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.