Abstract

The safe design of piping systems in a nuclear power plant requires structural analysis for all specified static and dynamic loads, including fluid dynamic forces due to operational and loss-of-coolant accident (LOCA) transients. For the reliable prediction of fluid forces, boundary conditions such as the characterisation of a closing isolation valve with the proper friction coefficient need to be carefully chosen. A valve model is described which implicitly determines the downstroke of the valve piston. Pre- and postcalculations were performed for the valve closure tests carried out during start-up at the BWR nuclear power plant at Krümmel, West Germany. The dynamic friction coefficient in a valve is introduced and its influence on the fluid dynamic forcing function in piping systems is examined.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.