Abstract

AbstractThe present article deals with transient thermal stress calculation on a safety horizontal shell and tube condenser. This condenser is used in a power plant for cooling of hot steam diverted from the turbine in the case of its emergency shutdown. The standard stress calculation was provided according to the EN 13445 standard in steady regime. As consistent with this calculation, an expansion joint must be used on the shell. The main aim of this article is to describe a detailed calculation of the transient temperature field on the shell and tubes, using finite element method analysis, and longitudinal thermal stresses on the shell and tubes during the start‐up process. Transient analyses are useable for more accurate EN 13445 calculation and, furthermore, for fatigue calculation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.