Abstract

A transient thermal stress analysis of threaded-adhesive joints applied in a non-magnetic Dewar at cryogenic temperature was conducted using the finite element method (FEM). A large temperature gradient was observed in the adhesive fillet region of the lower threaded-adhesive joint at the beginning of the cooling process. This caused a transient thermal stress that was much higher than that at the steady state. The peak von Mises stress of the lower adhesive joint reached the maximum value of 189 MPa at about 10 s after the introduction of liquid nitrogen into the Dewar and was 149% larger than the maximum thermal stress at the steady state. Attention should be paid on this serious transient thermal stress in the design and usage of non-magnetic Dewar.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.